Miniature Circuit Breakers (lower Rating)
 

AECO MCB, A simple looking device is a perfect technological  combination of switching and protection devices to provide maximum protection with minimum cost. Such features have made AECO MCBs suitable for a wider variety of applications especially where MCBs were previously considered unsuitable.

Characteristic

Suitable for control and protection of circuits having imP9rtant transient currents such as large motors.

TECHNICAL AND ECONOMIC ADVANTAGES

  •  High short circuit making and breaking capacity.
  • Current limiting for low let through energy and maximum safety
  • Very good selectivity related to upstream circuit breakers and back up protection fuses.
  • Protection to downstream switchgear applications and electrical equipment.
  • Inexpensive, near fuseless, distribution systems since high short circuit, no costs of spare fuses and stocking.
  • No faults due to ageing
  • Various versions for specific applications.
  • Compact dimensions and modular constructions.
  • Wide range of DBs and consumer units for ease of installation.
DC-Series -DC applications

Idealy suited for applications in DC circuits also. They cope with short circuit currents upto 1 kA.

The time constant (T=LR/C) of the consumer circuit is the decisive factor in interrupting DC currents. Voltages upto 220 V per pole can be switched at time constants < 5ms. The tripping characteristics may vary as per customer's requirement. Normal B, C or D characteristic AECO MCBs may be used upto 72V on d.c. upto 1.5 kA short -circuit capacity. The d.c. current does not have any effect on the tripping times in thermal range but the minimum current for instantaneous magnetic operation will be :t40% higher than at AC.
AECO DC MCBs are also designed for Railway applications as per SPEC/E-12/1/04.

 

CHARACTERISTIC CURVES

GENERAL TECHNICAL DATA

Voltage ratings 240/415 v AC, 220 VDC
Current ratings 0.5...............................63A
No. of poles 1,1+N,2,3+n,4
Specifications IS: 8828-1996 IEC 898-1995
BS 3871,VDE0641
Short circuit 10 kA certified as per
breaking capacity IS:8828-1996/IEC 898-1995 at 240/415 V 10KA at 220/380 V as per VDE
Rated frequency 50-60 Hz
Installation position Any
Electrical endurance >50,000 operating cycles
Mechanical endurance >100,000 operating cycles
Mounting Quick mounting on DIN rail 35 mm
Permissible ambient -25...............................+550C
temperature acc. to VDE 0664 parts 1 and 2
Protection class IP 30 as per IS:2147, VDE0106
Connection 1.....................................35mm
crossection

AECO MCBs are available with four types of characteristic tripping curves for different types of applications they are put to. These curves are shown in the chart below.

 

photo

 
B Characteristic
Suitable for installations having only resistive loads such as: electrical heating, ovens, geysers, GLS, lamps, electric iron stoves etc. These type are also used for protection of distribution equipment like wires, cables, metering equipment etc.
 
C Characteristic

Suitable for small inductive loads such as small motors, air conditioners etc.