Miniature Circuit
Breakers (lower Rating) |
|
|
|
|
AECO MCB, A simple looking device is a perfect
technological combination of switching and protection devices to
provide maximum protection with minimum cost. Such features have made AECO
MCBs suitable for a wider variety of applications especially where MCBs were
previously considered unsuitable. |
Characteristic
Suitable for control and protection of circuits having imP9rtant
transient currents such as large motors. |
|
|
|
|
TECHNICAL AND ECONOMIC ADVANTAGES |
|
- High short circuit making and breaking capacity.
- Current limiting for low let through energy and maximum safety
- Very good selectivity related to upstream circuit breakers and back up
protection fuses.
- Protection to downstream switchgear applications and electrical
equipment.
- Inexpensive, near fuseless, distribution systems since high short
circuit, no costs of spare fuses and stocking.
- No faults due to ageing
- Various versions for specific applications.
- Compact dimensions and modular constructions.
- Wide range of DBs and consumer units for ease of installation.
|
DC-Series -DC applications Idealy
suited for applications in DC circuits also. They cope with short circuit
currents upto 1 kA.
The time constant (T=LR/C) of the consumer circuit is the decisive factor
in interrupting DC currents. Voltages upto 220 V per pole can be switched at
time constants < 5ms. The tripping characteristics may vary as per
customer's requirement. Normal B, C or D characteristic AECO MCBs may be
used upto 72V on d.c. upto 1.5 kA short -circuit capacity. The d.c. current
does not have any effect on the tripping times in thermal range but the
minimum current for instantaneous magnetic operation will be :t40% higher
than at AC.
AECO DC MCBs are also designed for Railway applications as per
SPEC/E-12/1/04.
|
|
|
|
|
CHARACTERISTIC CURVES |
|
GENERAL TECHNICAL DATA |
| Voltage ratings |
240/415 v AC,
220 VDC |
| Current ratings |
0.5...............................63A |
| No. of poles |
1,1+N,2,3+n,4 |
| Specifications |
IS: 8828-1996
IEC 898-1995
BS 3871,VDE0641 |
| Short circuit |
10 kA certified
as per |
| breaking
capacity |
IS:8828-1996/IEC
898-1995 at 240/415 V 10KA at 220/380 V as per VDE |
| Rated frequency |
50-60 Hz |
| Installation
position |
Any |
| Electrical
endurance |
>50,000
operating cycles |
| Mechanical
endurance |
>100,000
operating cycles |
| Mounting |
Quick mounting
on DIN rail 35 mm |
| Permissible
ambient |
-25...............................+550C |
| temperature |
acc. to VDE 0664
parts 1 and 2 |
| Protection class |
IP 30 as per
IS:2147, VDE0106 |
| Connection |
1.....................................35mm |
| crossection |
|
|
|
AECO MCBs are available with four types of characteristic
tripping curves for different types of applications they are put to. These
curves are shown in the chart below. |
|
|
|
photo |
|
|
|
B Characteristic |
Suitable for installations having only resistive loads such as: electrical
heating, ovens, geysers, GLS, lamps, electric iron stoves etc. These type
are also used for protection of distribution equipment like wires, cables,
metering equipment etc.
|
|
C Characteristic |
|
Suitable for small inductive loads such as small motors,
air conditioners etc. |
|
|
|
 |
|
|
 |
 |
|